您的位置: 首頁 > 技術文章 > 淺談(tan)醫(yi)院電路故障引(yin)起(qi)的(de)安全用電的(de)問題及管理對策

淺談醫院電路故障引起的安全用電的問題及管理對策

更新(xin)日(ri)期:2022-04-06瀏覽:450次

簡婷

(安科瑞電(dian)氣股份有限公司上海嘉定201801)


摘 要:近年來(lai)(lai),醫(yi)療(liao)電(dian)(dian)(dian)氣(qi)化程度越來(lai)(lai)越高,醫(yi)護人員接觸到的(de)電(dian)(dian)(dian)器(qi)設(she)備(bei)迅速增(zeng)加(jia)(jia),保障(zhang)(zhang)醫(yi)院(yuan)安(an)全(quan)(quan)用電(dian)(dian)(dian) 已成為醫(yi)院(yuan)乃至全(quan)(quan)社會(hui)關(guan)注的(de)重點(dian)。當前醫(yi)院(yuan)安(an)全(quan)(quan)用電(dian)(dian)(dian)方面的(de)問題很多,包括部分供(gong)(gong)電(dian)(dian)(dian)線(xian)路(lu)和電(dian)(dian)(dian)力設(she)備(bei)老化、用 電(dian)(dian)(dian)管(guan)理制(zhi)(zhi)度不嚴(yan)、重點(dian)科室(shi)缺乏制(zhi)(zhi)定特定的(de)供(gong)(gong)電(dian)(dian)(dian)方案(an),以及醫(yi)護人員對安(an)全(quan)(quan)用電(dian)(dian)(dian)的(de)認識和重視不夠。管(guan)理對策包 括:加(jia)(jia)強醫(yi)院(yuan)供(gong)(gong)電(dian)(dian)(dian)線(xian)路(lu)的(de)規范和安(an)裝,加(jia)(jia)強線(xian)路(lu)管(guan)理制(zhi)(zhi)度,加(jia)(jia)強對重點(dian)科室(shi)的(de)電(dian)(dian)(dian)力保障(zhang)(zhang)等。

關鍵詞:醫院;安(an)全用(yong)電;管(guan)理對(dui)策

0 引言

      近年來(lai),醫(yi)療(liao)電(dian)氣化(hua)程度越來(lai)越高,醫(yi)護人(ren)員接觸(chu)到的(de) 電(dian)器設備迅(xun)速增加(jia),保障(zhang)醫(yi)院安(an)全(quan)(quan)(quan)用電(dian)已成為(wei)醫(yi)院乃(nai)至(zhi)(zhi)全(quan)(quan)(quan)社(she) 會關注的(de)重(zhong)點(dian)。一(yi)旦出現安(an)全(quan)(quan)(quan)用電(dian)問題,不僅可(ke)能會導(dao)致醫(yi) 療(liao)設備無法(fa)正常工作(zuo),甚(shen)至(zhi)(zhi)還(huan)可(ke)能直(zhi)接威脅患者及操(cao)作(zuo)人(ren)員 的(de)生(sheng)命安(an)全(quan)(quan)(quan)。因(yin)此,做好醫(yi)院安(an)全(quan)(quan)(quan)用電(dian)管(guan)理,是醫(yi)院后(hou)勤工 作(zuo)的(de)重(zhong)中之重(zhong)。

1 當前醫院安全用電方面問題

1.1部(bu)分供電(dian)(dian)線路和電(dian)(dian)力設備(bei)老化

      當前,我國醫(yi)院(yuan)整體電(dian)力(li)配置和(he)醫(yi)療設備(bei)已(yi)較為完善, 但仍有一些醫(yi)院(yuan)因建成已(yi)久,存(cun)在供電(dian)線路和(he)電(dian)力(li)設備(bei)老化、 用電(dian)線路不合理、醫(yi)療設備(bei)陳舊等現象⑴。一旦醫(yi)院(yuan)患(huan)者增(zeng)(zeng) 多(duo),用電(dian)量(liang)增(zeng)(zeng)大(da)時(shi),勢(shi)必會(hui)給用電(dian)安全(quan)帶(dai)來巨(ju)大(da)的安全(quan)隱患(huan)。

1.2用電管(guan)理(li)制度(du)不(bu)嚴

      個(ge)別醫院在日常工作中(zhong),相關(guan)安(an)全用電制(zhi)度(du)沒有落到實 處,沒有對用電情況(kuang)進行定(ding)期巡檢和維護。

1.3重點科室缺乏(fa)制定(ding)特(te)定(ding)的供(gong)電(dian)方案

      醫院有很多重點科室,如手術室、ICU、搶救室、血透 室等,若沒有制定特定的供電方案,突發停電時將嚴重影響 患者的治療和醫療設備的使用壽命。

1.4醫護人員對安全用(yong)電的認識(shi)和重視不夠(gou)

      醫護人員是醫療設備的直接使用者,一般也是早發現 醫療設備存在安全隱患或發生故障的人員。但如果思想上不 夠重視,沒有嚴格按照操作規范進行使用,發現隱患或故障 沒有及時報修,那么就容易導致用電事故的發生。

2 安全用電管理對策

2.1加強醫院供電線路的規范(fan)和安(an)裝

      (1)嚴把采購關。采購的設備必須符合國家電氣安全標 準,有質量合格證書。

      (2)嚴把安裝關。供電線路、各類電 器與醫療設備設施的安裝,必須符合國家電氣工程安裝要求的 標準,必須注意防潮、防塵,安裝附屬設施時也必須符合醫療 設備的配套要求。

      (3)插座接線要安全可靠。病房及各醫療 單元中所有插座都應按規定接線,火線、零線、地線不可調 換,特別注意零線和地線不可接錯。病房及各醫療單元中都要 安裝等電位接地系統,嚴禁將水龍頭、水管等做接地線,否則 一臺設備外殼漏電,則水龍頭、水管就成為帶電體,容易發生 觸電事故。

      (4)線路上安裝斷路器。在各分電流前安裝帶漏 電保護功能的斷路器,在儀器設備發生漏電、觸電或線路超負 荷時斷路器自動跳閘,切斷電源保護人身和儀器設備的安全。 

      (5)減少插線板使用。有些醫院進行新建、改建項目前,沒 有根據科室需要,進行強弱電設計,這樣在使用時容易出現 插座數量不足或位置不佳的情況,只有使用插線板進行補救。 可插線板使用往往存在兩個問題:一是電源線拖在地上,不 夠美觀,不便打掃;二是插線板落地容易被水侵入,發生短 路。去年,我院就發生過一起因半夜水管爆裂,水漫入插線 板里,造成整個科室短路跳閘的事故。之后,我院總結經驗, 收回了各科室的落地插線板,在墻上按需新增插座。

2.2 加強(qiang)線路管理制(zhi)度(du)

      (1)建立和完善安全用電管理制度。我院成立由分管副 院長牽頭,由總務基建科科長、維修保障科科長及科室成員 組成的安全用電管理小組,責任到人。

      (2)加強對線路的日 常巡查。我院固定每周二由院領導對科室進行巡查,每周一、 三、五由維修保障科進行巡查,對醫院用電線路進行抽查和 全面排查,將安全隱患消滅在萌芽狀態。

      (3)堅持持證上崗 制度。電氣設備的操作與維修人員必須經過培訓后取得上崗 證書才能上崗,嚴禁無證上崗。

      (4)病房電源嚴禁醫療設備 外的其他用電設備使用。我們在日常巡查時發現,有個別保 姆私帶電飯煲等電器接在設備帶上使用,如此極易導致線路 過負荷而跳閘,影響病患的正常治療。

2.3加強對(dui)重點科(ke)室的電(dian)力(li)保(bao)障

      (1)大型醫院一般采用雙路市電供電,并將手術室、 ICU、搶救室、血透室等重要負荷列為一級負荷,在突發停 電時必須優先保證一級負荷供電的可靠性和穩定性。醫院還 應配有柴油發電機,由專人負責定期檢查和啟動試驗,以保 證應急需要。此外,去年我院ICU還在雙路供電的基礎上, 新增了 UPS備用電源,進一步保證供電穩定性。

      (2)為保證 患者安全,手術室內配電、磁共振機、CT機、大型介入機等 與患者接觸的電源部分,應盡量考慮用單相電。

      (3)許多醫 院的醫療設備和信息系統一般都配有穩壓器,還應配備濾波 系統以減少電網的電磁干擾,使醫療設備正常工作,給醫務 人員提供真實、準確的信息。

2.4提高醫院人員的安全用電意識

      (1)做好安全用電的宣傳教育工作。通過醫院網站、電 子屏、院刊、微信公眾號、講座等宣傳形式,增強全員安全 用電意識,營造一個良好的安全用電環境。

      (2)請專業技術 人員對各類用電人員進行培訓。要讓醫護人員掌握安全用電 基本知識和所用設備的性能及操作規范,有效提高他們安全 用電意識,切實消除事故隱患,確保醫院安全用電落到實處。 

      (3)定期開展院內停電應急演練,并做好相關考核工作。

總(zong)之,醫(yi)(yi)院安全(quan)(quan)用(yong)(yong)電管(guan)(guan)理是一(yi)項復雜的系統(tong)工程,必須 全(quan)(quan)院職(zhi)工在思想上高度重視,加強安全(quan)(quan)用(yong)(yong)電管(guan)(guan)理,保(bao)證(zheng)醫(yi)(yi)院 工作(zuo)正常的開展(zhan)和患者的安全(quan)(quan)。

安科瑞為醫院安全用電提供的解決方案

安科瑞Acrelcloud-6000安全用電云平臺

      安科瑞電(dian)(dian)(dian)(dian)氣(qi)(qi)(qi)推出(chu)的(de)(de)(de)安全用(yong)(yong)電(dian)(dian)(dian)(dian)監控(kong)云(yun)系統采(cai)用(yong)(yong)研發的(de)(de)(de)剩(sheng)余(yu)(yu)電(dian)(dian)(dian)(dian)流(liu)(liu)互感器(qi)(qi)、溫(wen)(wen)度傳感器(qi)(qi)、電(dian)(dian)(dian)(dian)氣(qi)(qi)(qi)火(huo)災(zai)(zai)探(tan)測器(qi)(qi)、故障電(dian)(dian)(dian)(dian)弧(hu)探(tan)測器(qi)(qi)、電(dian)(dian)(dian)(dian)氣(qi)(qi)(qi)防(fang)火(huo)限流(liu)(liu)式保護(hu)器(qi)(qi)和中(zhong)性安防(fang),對引發電(dian)(dian)(dian)(dian)氣(qi)(qi)(qi)火(huo)災(zai)(zai)的(de)(de)(de)主要(yao)因素(導線溫(wen)(wen)度、電(dian)(dian)(dian)(dian)流(liu)(liu)、剩(sheng)余(yu)(yu)電(dian)(dian)(dian)(dian)流(liu)(liu)、故障電(dian)(dian)(dian)(dian)弧(hu)等(deng))進(jin)行不(bu)間(jian)斷的(de)(de)(de)數據與統計分(fen)析,并將(jiang)發現(xian)(xian)的(de)(de)(de)各種隱患信息及時(shi)推送給學(xue)校管理人員,指(zhi)導學(xue)校實現(xian)(xian)時(shi)間(jian)的(de)(de)(de)排查和治理,達到潛在電(dian)(dian)(dian)(dian)氣(qi)(qi)(qi)火(huo)災(zai)(zai)隱患,實現(xian)(xian)“防(fang)患于未然"的(de)(de)(de)目的(de)(de)(de)。

用戶(hu)可以(yi)利(li)用PC、手機(ji)、平(ping)板電腦等多種終(zhong)端實現對(dui)平(ping)臺(tai)的(de)(de)(de)訪問,查詢包括系(xi)統信(xin)息(xi)、實時數據、報記(ji)錄等在內的(de)(de)(de)各種信(xin)息(xi),使(shi)用方便。利(li)用該系(xi)統為用戶(hu)提供的(de)(de)(de)低(di)成本服務(wu),能有提升企業的(de)(de)(de)消防管理和電氣設備(bei)水平(ping),防范重大(da)惡性(xing)火災財產損失、尤其是重大(da)惡性(xing)人員傷亡責任的(de)(de)(de)發生(sheng)。

本系統的整體(ti)結構如圖所示:

image.png

硬件配置:

平(ping)臺服務器(qi):建議按照(zhao)我方提供配(pei)置標準(zhun)購買,或者客戶自己租用(yong)阿里云資源(yuan)。

站控管理層硬件配(pei)置:(如申請(qing)阿里云(yun)可忽略)

image.png

現場儀表硬件配置

image.png

現場儀表選型介紹--剩余電流火災探測器

image.png

現場儀表選型--故障電弧探測器

image.png

現場儀表選型--電氣防火限流式保護器

image.png

現場儀表選型中性安防保護器

      中(zhong)性線的定(ding)義(yi):三相電的星形(xing)接法是把每一相電源或負載(zai)的一端都接在中(zhong)性點上,將(jiang)中(zhong)性點

引(yin)(yin)出的這條線(xian)(xian)叫中性線(xian)(xian),這樣就形成(cheng)三相(xiang)四線(xian)(xian)制或者五線(xian)(xian)制。也可不引(yin)(yin)出,形成(cheng)三相(xiang)三線(xian)(xian)制。現

在(zai)的(de)低壓配電線路,采用多的(de)是三相(xiang)四線制,其中(zhong)的(de)三條線路分別用A、B、C代表(biao)三相(xiang),另一條中(zhong)性(xing)線用N代表(biao)。

      在(zai)三(san)相四線(xian)制或五線(xian)制供電系統運(yun)行過程中,中性線(xian)引發(fa)火災(zai)事故(gu)主要通過三(san)種途徑:

      A.中性線長(chang)期(qi)過載(zai)導致中性線絕緣層老化,后使得(de)絕緣層燃燒引(yin)發(fa)火災;

      B.中(zhong)性(xing)線故障使(shi)中(zhong)性(xing)線開(kai)路,導致三相電嚴重不平衡,燒毀電氣設備引發(fa)火災。

      C.中(zhong)性線老(lao)化(hua)使線路部過熱(re),導致中(zhong)性線絕緣層(ceng)老(lao)化(hua),后(hou)使得絕緣層(ceng)燃燒引(yin)發火災。

image.png

1)產品型號

image.png

2) 模塊接口示意

image.png

3)產品尺寸

image.pngimage.png


image.png

5 結語

      大型(xing)綜合醫院(yuan)(yuan)集醫療(liao)(liao)、護理(li)、科研、預防保健于一體,可(ke)靠(kao)、安(an)(an)全(quan)的(de)(de)電(dian)(dian)氣系統是保障醫院(yuan)(yuan)安(an)(an)全(quan)正常運行的(de)(de)基礎。大型(xing)綜合醫院(yuan)(yuan)后勤科室,特別是電(dian)(dian)力管理(li)部門要(yao)加強供(gong)電(dian)(dian)可(ke)靠(kao)性、醫療(liao)(liao)設(she)備(bei)漏電(dian)(dian)流處(chu)理(li)以(yi)及完善相關規章管理(li)制(zhi)度等方面的(de)(de)思考,大限(xian)度地降(jiang)低醫院(yuan)(yuan)電(dian)(dian)氣安(an)(an)全(quan)事故(gu),保障醫院(yuan)(yuan)電(dian)(dian)氣安(an)(an)全(quan)生產,為(wei)醫護人員及患者提供(gong)安(an)(an)全(quan)可(ke)靠(kao)的(de)(de)用電(dian)(dian)環境,為(wei)維持醫院(yuan)(yuan)正常的(de)(de)醫療(liao)(liao)秩序(xu)提供(gong)有效的(de)(de)后勤保障。

參考文獻

[1]朱先(xian)斌.對當前醫(yi)院用電安全與(yu)管理方面的幾點探討

[2]南楠(nan).淺談醫院的安全用電

[3]章天(tian)柱(zhu) .醫(yi)院安全(quan)用(yong)電的問題及管理對策

  [4]安科(ke)瑞企業微電網(wang)設計(ji)與應用手冊.2020.06版

作者簡介:簡(jian)婷(ting),女(nv),安(an)科瑞(rui)電氣股份有限(xian)公(gong)司,主要(yao)研(yan)究方向為醫院安(an)全用(yong)電云平(ping)臺系統的研(yan)發與(yu)應用(yong)。

 