【摘要】: 本文(wen)介紹(shao)了地鐵工(gong)(gong)(gong)程(cheng)中(zhong)消(xiao)防(fang)設(she)備電(dian)(dian)(dian)源(yuan)(yuan)監(jian)控(kong)(kong)系統(tong)(tong)設(she)置(zhi)的(de)必要(yao)性及(ji)規(gui)范要(yao)求(qiu),分析了監(jian)控(kong)(kong)設(she)計方案(an),提(ti)出該系統(tong)(tong)在(zai)地鐵工(gong)(gong)(gong)程(cheng)中(zhong)的(de)應用要(yao)求(qiu)及(ji)建(jian)議,以供地鐵工(gong)(gong)(gong)程(cheng)建(jian)設(she)參(can)考。消(xiao)防(fang)設(she)備電(dian)(dian)(dian)源(yuan)(yuan)監(jian)控(kong)(kong)系統(tong)(tong)主要(yao)針對消(xiao)防(fang)用電(dian)(dian)(dian)設(she)備的(de)電(dian)(dian)(dian)源(yuan)(yuan)進行實時(shi)的(de)監(jian)控(kong)(kong),通過檢測(ce)電(dian)(dian)(dian)壓、電(dian)(dian)(dian)流、開關狀(zhuang)態等有關參(can)數,判斷消(xiao)防(fang)設(she)備的(de)電(dian)(dian)(dian)源(yuan)(yuan)是否處(chu)于正常工(gong)(gong)(gong)作狀(zhuang)態的(de)監(jian)控(kong)(kong)系統(tong)(tong);一旦火災發(fa)生時(shi),確保消(xiao)防(fang)設(she)備電(dian)(dian)(dian)源(yuan)(yuan)時(shi)刻(ke)處(chu)于正常狀(zhuang)態,保證(zheng)消(xiao)防(fang)設(she)備可靠運行。

【關鍵詞】:消防設備電(dian)源監控系統;電(dian)壓/電(dian)流傳感器;監控主機;地(di)鐵工程


1 引言

     隨著中國經濟和科學技術的(de)(de)(de)迅速(su)發(fa)(fa)展,城(cheng)市建(jian)設越來越快(kuai),進入城(cheng)市的(de)(de)(de)人口越來越多,城(cheng)市建(jian)設逐漸向高密集型、智(zhi)能化方向發(fa)(fa)展,隨之而(er)來的(de)(de)(de)火災(zai)(zai)隱患也在大大增加,現代(dai)大體(ti)量建(jian)筑(zhu)、公眾集聚場所建(jian)筑(zhu)和一(yi)類高層建(jian)筑(zhu)越來越多,其消(xiao)防(fang)(fang)(fang)控制中心控制著自動報警系(xi)(xi)(xi)(xi)統(tong)(tong)(tong)、自動噴灑系(xi)(xi)(xi)(xi)統(tong)(tong)(tong)、消(xiao)防(fang)(fang)(fang)事故廣播系(xi)(xi)(xi)(xi)統(tong)(tong)(tong)、防(fang)(fang)(fang)排煙(yan)系(xi)(xi)(xi)(xi)統(tong)(tong)(tong)、氣體(ti)滅火系(xi)(xi)(xi)(xi)統(tong)(tong)(tong)、消(xiao)火栓系(xi)(xi)(xi)(xi)統(tong)(tong)(tong)、應急照(zhao)明系(xi)(xi)(xi)(xi)統(tong)(tong)(tong)等(deng)多個消(xiao)防(fang)(fang)(fang)安(an)全(quan)系(xi)(xi)(xi)(xi)統(tong)(tong)(tong)的(de)(de)(de)操作,是建(jian)筑(zhu)消(xiao)防(fang)(fang)(fang)安(an)全(quan)的(de)(de)(de)關鍵,而(er)消(xiao)防(fang)(fang)(fang)控制室(shi)的(de)(de)(de)火災(zai)(zai)報警系(xi)(xi)(xi)(xi)統(tong)(tong)(tong)以及相關的(de)(de)(de)消(xiao)防(fang)(fang)(fang)聯動設備(bei)(bei)能否正常工作,又取決于消(xiao)防(fang)(fang)(fang)設備(bei)(bei)電源的(de)(de)(de)工作狀態。若(ruo)其電源出現故障,將造成火災(zai)(zai)蔓延,嚴(yan)重(zhong)威(wei)脅生(sheng)命(ming)財產安(an)全(quan)。

     ;地(di)鐵工程(cheng)構造(zao)復雜、人員密集(ji),且設(she)(she)備眾多,消(xiao)(xiao)防(fang)安全設(she)(she)計一直備受關注。在火災情況下,如(ru)果消(xiao)(xiao)防(fang)設(she)(she)備電源不能可(ke)(ke)靠、穩(wen)定(ding)地(di)工作,投入(ru)大量資金(jin)的消(xiao)(xiao)防(fang)設(she)(she)施可(ke)(ke)能形同虛設(she)(she)。因此(ci),對消(xiao)(xiao)防(fang)設(she)(she)備電源進行實(shi)時(shi)監(jian)測,及時(shi)排除故障,保障設(she)(she)備在關鍵時(shi)刻穩(wen)定(ding)、可(ke)(ke)靠運行至關重要。


2 地鐵低壓配電系統

     地(di)鐵工程低(di)壓用(yong)電(dian)(dian)(dian)(dian)(dian)設備種類較多,根(gen)據GB 50157-2013《地(di)鐵設計規范》要求,負(fu)荷(he)分(fen)一級負(fu)荷(he)、二級負(fu)荷(he)、三級負(fu)荷(he)。消防設備屬于一級負(fu)荷(he),其中消防泵、疏散(san)扶梯(ti)、氣滅、應急照明(ming)、FAS、廢(fei)水泵、防火(huo)門等由變電(dian)(dian)(dian)(dian)(dian)所放射式配(pei)電(dian)(dian)(dian)(dian)(dian),就地(di)設置(zhi)雙電(dian)(dian)(dian)(dian)(dian)源(yuan)(yuan)切換配(pei)電(dian)(dian)(dian)(dian)(dian)箱;環控類消防負(fu)荷(he)如防排煙風(feng)機、防火(huo)排煙閥(fa),由環控消防負(fu)荷(he)電(dian)(dian)(dian)(dian)(dian)控柜配(pei)電(dian)(dian)(dian)(dian)(dian),設雙電(dian)(dian)(dian)(dian)(dian)源(yuan)(yuan)切換裝置(zhi)。


3 消防設備電源監控系統方案

3.1系統概述

     該監控系統對(dui)消防設備電源(yuan)狀態進行實時監測,由消防電源(yuan)設備狀態監控器(監控主機)、傳感器、通信(xin)線(xian)等組成。電壓/

     電流(liu)傳感器采集消防電源(yuan)的電壓(ya)、電流(liu)信息(xi)并(bing)上傳至監控主(zhu)機;監控主(zhu)機對電壓(ya)、電流(liu)進行分析,診(zhen)斷(duan)出過壓(ya)、欠壓(ya)、過流(liu)、缺相等故障(zhang),顯示并(bing)報警,提示工作人員及(ji)時檢修(xiu),避免火災情(qing)況下消防設備因電源(yuan)故障(zhang)而無法正常(chang)運行。

3.2系統結構

     一般監控主機(ji)可(ke)監測2個(ge)回路,每(mei)個(ge)回路可(ke)連接64個(ge)傳(chuan)感(gan)器。當系(xi)統(tong)傳(chuan)輸距離(li)大(da)于500m時,需(xu)增(zeng)加區(qu)域分(fen)機(ji)擴(kuo)展通訊距離(li)。系(xi)統(tong)結(jie)構(gou)如圖(tu)1所(suo)示。對于現場消防設(she)(she)備較多的建筑,可(ke)分(fen)區(qu)域監測。各區(qu)域設(she)(she)區(qu)域分(fen)機(ji),區(qu)域分(fen)機(ji)經(jing)總線與消防控制室的系(xi)統(tong)主機(ji)通信,組成(cheng)大(da)型監控系(xi)統(tong)網(wang)絡結(jie)構(gou)。

image.png

圖1 監控(kong)系統結構圖

3.3監控原理

     根據配(pei)(pei)電(dian)需求(qiu)、消(xiao)防配(pei)(pei)電(dian)形式(shi)及產(chan)品特性,典型(xing)三相消(xiao)防配(pei)(pei)電(dian)電(dian)源(yuan)監測(ce)原理如圖2所示。

image.png

圖2 典型三相消(xiao)防(fang)電源(yuan)監測原理(li)圖

4 消防設備電源監控系統方案

4.1系統(tong)要求及配置

為滿足(zu)地鐵運營要求,系統應具備(bei)以(yi)下性能:

(1)穩定(ding)性(xing):故(gu)障時發出(chu)報警并精準顯示故(gu)障位(wei)置(zhi)、故(gu)障類別等信息;

(2)可擴(kuo)展性:具有靈活的對外接口(kou)形式,并采用通用協議(yi),實現與綜合監控(kong)系(xi)統互聯互通;

(3)可維護性:具(ju)備(bei)自我診(zhen)斷、故(gu)障(zhang)(zhang)隔離功能,以降低故(gu)障(zhang)(zhang)率、縮小故(gu)障(zhang)(zhang)范圍。

系統(tong)的主要設(she)備配置及(ji)安裝要求如(ru)表1、表2所示(shi)。

表(biao)1 系統配(pei)置(zhi)及安裝要求

設備配置(zhi)要求(qiu)安裝位置(zhi)

監控主(zhu)機(1)具(ju)備顯(xian)示、報警、存儲功能(neng);

(2)與傳感器(qi)采(cai)用(yong)(yong)二總線通信,與區域分機采(cai)用(yong)(yong)CAN總線通信,并可擴展車站控制室

信號傳感器(1)可監測單(dan)相(xiang)、三相(xiang)交流電(dian)壓及電(dian)流;

(2)具備總線通信接口;

(3)具(ju)有抗電(dian)(dian)磁(ci)力配電(dian)(dian)箱、配電(dian)(dian)柜內

區域分機(1)具備增(zeng)加(jia)通訊點位,擴展通訊距離;

(2)具(ju)有總線通信接口、總線故障隔離功能;

(3)適(shi)用(yong)于換乘車(che)站、場段、控制中心及(ji)區間聯(lian)絡通(tong)道(dao)配電(dian)間、電(dian)纜井、區間隧道(dao)壁

image.png

4.2監測原則

     綜合(he)考慮規范圖集要求、設(she)備投資及運營維(wei)護等(deng)各方面因素,有(you)選擇地進行電壓、電流(liu)傳感(gan)器設(she)置,選型表如(ru)表2所示。 建議地鐵工程消防(fang)電源監(jian)測項目如(ru)表3所示。

表2 傳感器選型表

image.png

表3 地鐵消防電源監測項目

image.png

5 結束語

     消(xiao)防(fang)(fang)設(she)(she)備(bei)(bei)(bei)電源監控系統可為地鐵工程消(xiao)防(fang)(fang)安全科學管理提供有力保(bao)障,顯著(zhu)提高消(xiao)防(fang)(fang)設(she)(she)備(bei)(bei)(bei)的可靠(kao)性(xing)(xing)、穩定性(xing)(xing)及(ji)備(bei)(bei)(bei)戰能力,讓消(xiao)防(fang)(fang)設(she)(she)備(bei)(bei)(bei)做(zuo)到“防(fang)(fang)消(xiao)結合、預防(fang)(fang)為主"。設(she)(she)計過(guo)程中(zhong)應根據地鐵站規模、消(xiao)防(fang)(fang)設(she)(she)備(bei)(bei)(bei)配(pei)電方式及(ji)產品特(te)點,綜(zong)合考慮功(gong)能性(xing)(xing)、經濟性(xing)(xing),靈活確定監控方案,以充分發揮該系統的作用。

參考文獻

[1].李(li)啟峰.地鐵(tie)消防(fang)設備電源監控系統設計與探討(tao).工程(cheng)建設與設計

[2].安科瑞企業微(wei)電網設計與(yu)應用(yong)手冊.2020.06版

[3].GB 25506-2010 消防控制室(shi)通用技術要求[S].

[4].GB 51348-2019 民用建筑電氣設(she)計標準[S].

[5].GB 28184-2011 消(xiao)防設備電源監控系(xi)統[S].

作者簡介:簡婷,女,本科(ke),現就職于安(an)科(ke)瑞(rui)電氣股(gu)份有限(xian)公司,主(zhu)要研究方向為建筑能耗監測系統。


 